Welcome to HDC !

Service Hotline: +86-371-66766667

Whatsapp: +86-15093102503

Email: info@hlcables.com

Home - Products - Cables&Wire - Control/Instument Cable


Tel: +86-371-66766667

Whatsapp: +86 15093102503

E-mail:info@hlcables.com

1-48 Pairs Individual Screen Armoured Instrument Cable

1-48 Pairs Individual Screen Armoured Instrument Cable

Voltage:Low

Conductor:Copper/Tinned Copper

Insulation:XLPE/PVC/PE

Cores:1,2,3,4,16,18,20,24,48 pairs

Standard:IEC/ASTM etc

Packaging:Iron or Wooden Drum

2-48 Pairs Individual Screen Armoured Instrument Cable Feature:
1. Conductor: Plain annealed copper, sizes: 0.5 mm² solid, 1.0 mm² solid, 0.5 mm² flexible, 0.75 mm² flexible or 1.5mm²stranded
2. Insulation: Polyethylene PE,  Colour code: black / white / red; with numbered tape under separator tape of the triple screen
3.Triple screen: 24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm²,   Wrapping: at least 1 layer of plastic tape
4. Collective screen: 24 µm aluminium / PETP tape over tinned copper drain wire, 0.5 mm²
5. Bedding: zero halogen flame retardant compound LSZH, black
6. Armour: galvanized round steel wires
7. Outer sheath: zero halogen flame retardant compound LSZH, black or blue for intrinsically safe systems
2-48 Pairs Individual Screen Armoured Instrument Cable application:
insutrumention cable Individual & Overall Screened Steel Wire Armored/ SWA Pairs is used in data processing and process control. Suitable for fixed
installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields.
1. Desing:     LSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, black & white , twisted pairs or black,white &
red twisted triples with continuous number sequence.Cables are manufactured strictly in accordance of UL as well as relevant Australian Standards. 
2. Voltage rating :Rated Voltage Max. 300V a.c; Nominal Voltage A.C/D.C 110/150V, Test Voltage In process spark test – 4500V and AC withstand
voltage test – 1500V, TECHNICAL DATA 0.5mm 1.5mm
3.Maximum Capacitance
Conductor to Conductor 145pF/m 200pF/m, Conductor to Screen 240pF/m 300pF/m, Maximum Conductor Resistance @ 20 C 38.4Ω/km 13.8Ω/km,
Insulation Resistance @ 20 C 40MΩ/km 140MΩ/km,  Cross Talk Attentuation Between Pairs @ 1kHz 300Ω 150Ω
Inductance @ 1kHz 1.00mH/km 0.95mH/km,  L/R Ratio @ 1kHz 13.7µH/Ω 36.5µH/Ω 
4.Operating Temperature
Minimum continuous operating temperature -25°C,75°C, 90°C,  Minimum short circuit temperature 160°C (for 5 sec)
5. Bending Radius:  The following minimum bending radius should be observed to ensure operating reliability
unarmoured: 9 x cable outer diameter (during installation)  6 x cable outer diameter (after installation)
Armoured: 18 x cable outer diameter (during installation)     12 x cable outer diameter (after installation)
6.Tensile strength
is armoured instrumentation cable
Cable maximum pulling tension (approximate) is limited to 65-70 N/mm² of the total cross-sectional area ofconductor.
7.Example:   3pairs 1.5 total cross sectional area 3x 2x1.5=9mm² 9mm² x 70Nmm² =630N (0.63kn)
For pulling by armour, the pulling tension should be limited to 130 N/mm² of the total cross-sectional of steel wire

is armoured instrumentation cable

is instrument cable types

  • Name:  
  • Email:   
  • Tel:  
  • Message: 

Contact Us

Email: info@hlcables.com

Service Hotline: +86-371-66766667

Whatsapp: +86 15093102503

Add: Room 601, Floor 6, Building 5, No. 80, Jinshui East Road, Zhengdong New District, Pilot Free Trade Zone, Henan, China.

Inquiry

Name: *
Tel: *
Email:   *
Message: *
      

Huadong Cable Group-Zhengzhou Hongliang Cable Co., Ltd © 2000-2023 Copyrights Galvanized Steel Wire

Inquiry

    • Name:  
    • Email:   
    • Tel:  
    • Message: